Holter Software-NET Version 12.0 Holter Software-TOP Version 12.0 Holter Hardware
Specifications & Features Specifications & Features Product Descriptions
  • Operation System: Windows 2000, Windows XP.

    • CPU: 1G Hz

    • Hard Disk: 40G

    • RAM: 256M

    • Monitor Resolution: 1024×768

    • Security Key: USB UltraPro

    • Printer: Laser printer or in-jet printer,   black&white or color.

  • Can analyze Holter ECG recordings from both 3–channel recorders and 12-lead recorders.

  • Enhanced ST analysis capability: 12-lead ST segment trend scan and comparison, operator can reset the ST markers for any designated time period for re-calculating. Comprehensive 12-lead 3-D ST-trends are presented for easy identification of ischemia locations.

  • Pacemaker analysis function enables the detailed study of pacemaker performance of various models: VVI, AAI, DDD, etc.

  • Unique “OSAS” (Obstructive Sleep Apnea Syndrome) analysis function. Other powerful functions are: patient event button auto-correlation, QT dispersion analysis, HRV (Heart Rate Variability) analysis (time domain, frequency domain and Lorenz poincare plot), branch bundle block analysis, atrial-fibrillation and atrial-flutter analysis, FCG CADgram (only for 12-lead recorders.), if 3-channel Holter recorders are used in orthogonal hookup, SAECG (Signal Averaged ECG) and VCG (Vector-cardiograph) analysis can be made.

  • T wave alterance analysis can be done upon any selected ECG episode.

  • Longer 12-second ECG strip can be printed for better arrhythmia observation.

  • Can get the 24-hour ABP monitoring data, create the ECG vs. ABP report.

  • Operator can transfer Holter report to remote location through Internet as easy as sending emails.

  • Strong database management capability makes it easy to search patient with combined conditions, can output to or inport from CD. Holter reports can be transferred to the database server computer by using the “ECG Network Information System (ECG-NIS) , all data can be shared electronically.

  • Can output ASCII data for further study and programming, support Germany GDT format.

  • User can translate the software into local language easily, if software is not available in certain languages.

  • If use A4 printing paper with ECG grid, can print ECG reports faster and use less ink when “Without Grid” is selected from software settings menu.

  • Can print reports in colors.

  • Operation System: Windows 2000, Windows XP.

    • CPU: 1G Hz

    • Hard Disk: 40G

    • RAM: 256M

    • Monitor Resolution: 1024×768

    • Security Key: USB UltraPro

    • Printer: Laser printer or in-jet printer,   black&white or color.

  • Arrhythmia Template Focus function (or DEMIX): superimposition is done for each template in 12 leads and the different ECG shapes can be easily discriminated and edited. Operator can re-arrange the template category quickly.

  • Ventricular escape beat analysis function: histogram is made according to the ectopic coupling intervals. Operator can re-arrange the template category quickly.

  • Atrial prematurity histogram: all the atrial premature beats are classified by their premature rate. Different atrial groups can be differentiated easily.

  • Heart Rate Turbulence (HRT) function (or VE Chaos) : HRT is the most powerful ECG-related risk predictor for assessing the death risk following myocardial infarction. The predictive value is comparable with that of the LVEF.

  • Can analyze Holter ECG recordings from both 3 –channel recorders and 12-lead recorders.

  • Enhanced ST analysis capability: 12-lead ST segment trend scan and comparison, operator can reset the ST markers for any designated time period for re-calculating. Comprehensive 12-lead 3-D ST-trends are presented for easy identification of ischemia locations.

  • Pacemaker analysis function enables the detailed study of pacemaker performance of various models: VVI, AAI, DDD, etc.

  • Unique “OSAS” (Obstructive Sleep Apnea Syndrome) analysis function. Other powerful functions are: patient event button auto-correlation, QT dispersion analysis, HRV (Heart Rate Variability) analysis (time domain, frequency domain and Lorenz poincare plot), branch bundle block analysis, atrial-fibrillation and atrial-flutter analysis, FCG CADgram (only for 12-lead recorders.), if 3-channel Holter recorders are used in orthogonal hookup, SAECG (Signal Averaged ECG) and VCG (Vector-cardiograph) can be made.

  • T wave alterance analysis can be done upon any selected ECG episode.

  • Longer 12-second ECG strip can be printed for better arrhythmia observation.

  • Can get the 24-hour ABP monitoring data, create the ECG vs. ABP report.

  • Operator can transfer Holter report to remote location through Internet as easy as sending emails.

  • Strong database management capability makes it easy to search patient with combined conditions, can output to or inport from CD. Holter reports can be transferred to the database server computer by using the “ECG Network Information System (ECG-NIS) , all data can be shared electronically.

  • Can output ASCII data for further study and programming, support Germany GDT format.

  • User can translate the software into local language easily, if software is not available in certain languages.

  • If use A4 printing paper with ECG grid, can print ECG reports faster and use less ink when “Without Grid” is selected from software settings menu.

  • Can print reports in colors.

  • When orthogonal XYZ-lead placement is applied, Vector-cardiograph can be printed, SAECG analysis can be performed for data at any time location, 12-lead ECG and V1R, V3R, V5R can be derived with high precision using software.

  • Auto-correlation of patient event button marks with Holter software.

  • Green and red lights signify normal and abnormal functions.

  • Electronic enrollment can be made for each new recording so that mislabeling of recorders is fully avoided.

  • To check hookup quality in wireless mode: use Holter blue-tooth transmitter to send out ECG data, use PDA to receive and display ECG (Holter blue-tooth transmitter and PDA are optional).

  • To check hookup quality in cable mode: use Holter insulation cable to transfer ECG from recorder to computer or laptop. Patient insulation (4000V AC) is guaranteed (Holter insulation cable is optional).

  • It takes only a few minutes to transfer whole ECG Data swiftly to PC or notebook computer with Holter USB playback cable. The recorder is designed such that patient cable and USB playback cable share one port of recorder, patient is then protected from any potential mains voltage hazard or current leakage.

Holter Recorder MGY-H3

    Lead: 3

    Storage: 256M Non-volatile flash memory

    Flash Card Model: ScanDisk-128

    Time: 168 Hour

    Sample Rate: 512Hz, Write Rate 128Hz.

    Size: 74mm×55mm×19mm

    Weight: 52g with battery

    Power Source: 1 AAA

    Data Output: 3-channel digital, for  real-time ECG data acquisition, or for hookup check.

    ECG Cable Model: SC-15F/7N

Holter Recorder MGY-H4

Lead: 12

    Storage: 256M Non-volatile flash memory

    Time: 36 Hour

    Sample Rate: 512Hz, Write Rate 256Hz.

    Size: 74mm×55mm×19mm

    Weight: 52g with battery

    Power Source: 1 AAA

    Data Output: 12-channel digital, for real-time ECG  data acquisition, or for hookup check.

    ECG Cable Model: SC-15F/10N

Holter Recorder MGY-H7

Lead: 12

    Storage: 256M compact flash card

    Flash Card Model: ScanDisk-128

    Time: 72 Hour

    Sample Rate: 512Hz, Write Rate 128Hz.

    Size: 74mm×55mm×19mm

    Weight: 52g with battery

    Power Source: 1 AAA

    Data Output: 12-channel digital, for real-time ECG

                        data acquisition, or for hookup check.

    ECG Cable Model: SC-15F/10N

Holter Recorder MGY-H7L

Lead: 3

    Storage: 128M compact flash card

    Flash Card Model: ScanDisk-128

    Time: 72 Hour

    Sample Rate: 512Hz, Write Rate 128Hz.(Sample rate is 1000Hz for the first 10 minutes, data used for SAECG analysis)

    Size: 7137mm×72mm×25mm

    Weight: 191g with battery

    Power Source: 2 AA

    Data Output: 12-channel digital, for real-time ECG

                        data acquisition, or for hookup check.

    ECG Cable Model: SC7-90

    3-channel ECG waves: Can be displayed on LCD monitor, the current working status can also be indicated: “No Card”, “Format Card”, “Bad Card”, “Recording”, “Record Over” and the time passed from start of recording. To activate LCD, press the panel side button.

Holter Recorder MGY-H7P

Lead: 2 conventional channels + 1 pacemaker channel

    Storage: 128M compact flash card

    Flash Card Model: ScanDisk-128

    Time: 72 Hour

    Sample Rate: 128Hz for 2 conventional channels and 4096Hz for 1 pacemaker channel.

    Size: 129mm×705mm×259mm

    Weight: 52g with battery

    Power Source: 1 AAA

    Data Output: 12-channel digital, for real-time ECG

                        data acquisition, or for hookup check.

    ECG Cable Model: SC7-90

Holter Recorder MGY-H8

Lead: 3

    Storage: 128M compact flash card

    Flash Card Model: ScanDisk-128

    Time: 72 Hour

    Sample Rate: 128Hz, Write Rate 128Hz.

    Size: 7134mm×70mm×26mm

    Weight: 142g with battery and flash card

    Power Source: 2 AA

    Data Output: Holter recorder for scientific research, multi-day recording for leads I, II, III.  Auto correlation of patient event button marks with Holter software.

    ECG Cable Model: SC4-100

Holter Recorder MGY-H9

Lead: 3

    Storage: 256M compact flash card

    Flash Card Model: ScanDisk-128

    Time: 24 Hour

    Sample Rate: 1024Hz,

    Size: 7134mm×70mm×26mm

    Weight: 145g with battery and flash card

    Power Source: 1 AA

    Data Output: Holter recorder for scientific research, sample rate is 1024Hz  recorded leads are I, II, III.  Auto correlation of patient event button marks with Holter software.

    ECG Cable Model: SC4-100

Holter Recorder MGY-H12

Lead: 12

    Storage: 128M compact flash card

    Flash Card Model: ScanDisk-128

    Time: 24 Hour

    Sample Rate: 128Hz,

    Size: 134mm×70mm×26mm

    Weight: 145g with battery and flash card

    Power Source: 1 AA

    Data Output: 12-lead Holter recorder, auto-correlation of patient event button marks with Holter software.  Recorded data can be used for 12-lead FCG Cadgram analysis, useful tool for CAD and ischemia research.

    ECG Cable Model: SC4-100

Holter Recorder MGY-H12M

Lead: 12

    Storage: 512M compact flash card

    Flash Card Model: ScanDisk-512

    Time: 24 Hour

    Sample Rate: 128Hz,

    Size: 134mm×70mm×26mm

    Weight: 155g with battery and flash card

    Power Source: 2 AA

    Data Output: 12-lead multi-day Holter recorder, auto-correlation of patient event button marks with Holter software.  Recorded data can be used for 12-lead FCG CADgram analysis, useful tool for CAD and ischemia research.

    ECG Cable Model: SC-L-100

Holter Recorder MGY-H12L

Lead: 12

    Storage: 128M compact flash card

    Flash Card Model: ScanDisk-128

    Time: 24 Hour

    Sample Rate: 128Hz,

    Size: 134mm×72mm×25mm

    LCD: Display 3-channel ECG and indications for recorder current status

    Weight: 191g with battery and flash card

    Power Source: 2 AA

    Data Output: 12-lead Holter recorder, auto-correlation of patient event button marks with Holter software.  3-channel ECG waves can be displayed on LCD monitor, the current working status can also be indicated: “No Card”, “Format Card”, “Bad Card”, “Recording”, “Record Over” and the time passed from start of recording. To activate LCD or to switch over every three channels, press the panel side button.  Recorded data can be used for 12-lead FCG CADgram analysis, useful tool for CAD and ischemia research.

    ECG Cable Model: SC-L-100

Flash Card Reader        Model:RW-018D

Communication Port:  USB

Card Type:  Compact Flash Card

Used With: Used with Holter recorders, applicable models are MGY-H7, MGY-H7L, MGY-H7P, MGY-H8, MGY-H9, MGY-H12, MGY-H12L and MGY-H12M.

Compact Flash Card Model:ScanDisk-256

Capacity:  256MB

Size:  36mm×43mm×4mm

Used With: Used with Holter recorders, applicable models are MGY-H7, MGY-H7L, MGY-H7P, MGY-H8, MGY-H9, MGY-H12, MGY-H12L and MGY-H12M.

Holter Insulation Cable Model:R/USB

Input Port:  Phone Jack

Output Port:  USB

Used With: Used with Holter recorders to observe real-time ECG waves on PDA or computer monitor. ECG is transmitted by the Holter blue-tooth transmitter and received by a PDA with blue-tooth module or a blue-tooth adapter connected to computer via USB port. Applicable Holter recorder models are MGY-H3, MGY-H3M, MGY-H4 and MGY-H4M.

Holter Blue-tooth Transmitter Model:MGY-RTB1

Transmission Distance:  5M clear space

Input Port:  Phone Jack

Used With: Used with Holter recorders to observe real-time ECG Waves on computer,  applicable models are MGY-H3, MGY-H3M, MGY-H4, MGY-H4M

Holter Blue-tooth Adapter Model:JINOU6261

Transmission Distance:  5M clear space

Input Port:  USB

Used With: Used with Holter recorders to observe real-time ECG waves on computer monitor. ECG is transmitted by the Holter blue-tooth transmitter and received by a blue-tooth adapter connected to computer via USB port. Applicable Holter recorder models are MGY-H3, MGY-H3M, MGY-H4 and MGY-H4M.

PDA                      Model:JINOU6261

Software Driver:  CD Included

Used With: Used with Holter recorders to observe real-time ECG waves on PDA monitor. ECG is transmitted by the Holter blue-tooth transmitter and received by a PDA with blue-tooth module. Applicable Holter recorder models are MGY-H3, MGY-H3M, MGY-H4 and MGY-H4M.

ECG  Cable                             Model:SC-15F/7N     

Electrode Type:  7 Snap

Device Connector: 15 pin                Length:720mm                               Color: 1+/Red, 1-/White, 2+/Brown, 2-/Black, 3+/Orange, 3-/Blue, N/Green.
Used With:  Used with Holter recorders, applicable models are MGY-H3 and MGY-H3M.

ECG  Cable                             Model:SC-15F/10N     

Electrode Type:  10 Snap

Device Connector: 15 pin                Length:9000mm                               Color: 1+/Red, 1-/White, 2+/Brown, 2-/Black, 3+/Orange, 3-/Blue, N/Green.
Used With:   Used with Holter recorders, applicable models are MGY-H7, MGY-H7L and MGY-H7P.

ECG  Cable                             Model:SC-4/100

Electrode Type:  4 Snap

Device Connector: Individual              Length: 1000mm                               Color: RA/Red, LA/Yellow, LL/Green, RL/Black.
Used With: Used with Holter recorders, applicable models are MGY-H8 and MGY-H9.

ECG  Cable                             Model:SC-L/100

Electrode Type:  10 Snap

Device Connector: Individual              Length:1100mm                               Color: RA/Red, LA/Yellow, LL/Green, RL/Black, C1/Red, C2/Yellow, C3 / Green, C4/Brown, C5/Black, C6/Purple.
Used With: Used with Holter recorders, applicable models are MGY-H12, MGY-H12M and MGY-H12L.

Table of Holter Recorders

 

Media

Hour

Lead

Sample Rate (Hz)

Battery

LCD

Event Button

Electronic Enrollment

VLP

VCG

Phone Transmission

MGY-H3

256M F.M

48

3

1024

 (W512)

1 AAA

NO

YES

YES

YES

NO

MGY-H3M

256M F.M

168

3

512

 (W128)

1 AAA

NO

YES

YES

YES

NO

MGY-H4

256M F.M

36

12

512

 (W256)

1 AAA